APPLICATION
The machine is intended for controlling the heat resistance at temperature differences set up in the technical documentation for glass packing for certain types of products (A method, GOST 13903-2016) and for testing the heat resistance while studying strength (B and C methods, GOST 13903-2016) of glass containers produced according
to the requirements of GOST 32131 and GOST 5717.1 (if requested by a customer).
OPERATION PRINCIPLE
The following is performed without an operator’s intervention:
- tank preliminary filling with water;
- reaching the required temperature in the tanks, including water temperature decrease to the water supply line temperature in the cold tank;
- holding time counting;
- transporting samples tested from tank to tank.
TECHNICAL SPECIFICATIONS
|
Characteristics
|
Parameters
|
|
Power supply
|
3x380 V, 50 Hz
|
|
Power input
|
max 25.5 kW
|
|
Weight
|
max 330 kg
|
|
Overall dimensions (WxDxH)
|
max 2050x1490x1850 mm
|
|
Weight of samples tested
(with the required volume of 8 l/kg)
|
max 31.2 kg
|
|
Range of maintaining the set up water temperature
in the hot tank
|
from water supply line temperature
up to 97°C
|
|
Accuracy of maintaining the set up water temperature
in different parts of the tank
|
± 0,5°С
|
|
Time for automatic transfer of the basket
with glass containers from tank to tank
|
max 13 seconds
|